Performance
| Measuring range | ±10° ±15° ±20° ±30° ±45° ±60° ±85° (single axis Z / dual axis XY) 360° (±180°) single axis Z |
| Accuracy (Factory verification @25 °C) | ≤ ± 0.5% FS |
| Temperature coefficient @ 0° | Typical < ±0.006°/°K |
| Long term repeatability | Single axis: Typical <±0.5° in the range ±180° Dual axis: Typical <±0.5° in the range ≤ ± 60°, ± 2° otherwise |
| Resolution | 0.01° CANopen output; 12 bit analog output |
Electrical specifications
| Electrical connections | M12 connector or cable |
| Output signal | CANopen, Ratiometric 10-90% of Vs, 0.5 – 4.5 V DC, 0-10 V DC or 4-20 mA |
| Supply voltage | CANopen, 0.5–4.5 V DC, 4–20 mA: 10–36 V DC, 0–10 V DC : 11–36 V DC Ratiometric: 10-90% of Vs: 5 V DC |
| Current consumption | Analogue: < 20 mA / pr. channel (no load) CANopen/J1939: < 15 mA /per channel (no load) |
| MTTFd [Years] | CANopen: 631 (Single channel) Analogue: 731 (Single channel) |
Environmental conditions
| Operating temperature range | -40 – 85 °C | ||
| EMC | Emission | EN 55011 | |
| Immunity | EN 61236-3-2 | ||
| Vibration stability | Sinusoidal | 20 g, 10 Hz – 2,000 kHz | IEC 60068-2-6 |
| Shock resistance | Impulsive on 3 axes | 50 g, 11 ms | IEC 60068-2-27 |
| IP rating | IP67, IPX9K | ||
Mechanical characteristics
| Materials | Enclosure | PBT (Polybutylene terephthalate) |
| Net weight | 0.26 kg (without cable) | |
Dimensions
Electrical connections
Ordering
| Type | Output signal | Configurations | Code no. |
| DST X720 | 36 V CANopen | 1 x M12 5p; Single axis; ±180°; 36 V | 098G3000 |
| 36 V CANopen | 2 x M12 5p; Single axis; Redundant; ±180°; 36 V | 098G3001 | |
| 36 V CANopen | 1 x M12 5p; Dual axis; ±85°; 36 V | 098G3002 | |
| 36 V CANopen | 2 x M12 5p; Dual axis; Redundant; ±85°; 36 V | 098G3003 |
Ordering code – on request
| Electrical connections | |
| M12 connector output | M |
| Cable output (specify cable length) | F |
| Axis type | |
| Dual axis (XY axis) | O |
| Single axis (Z axis) | V |
| Circuit type | |
| Single | S |
| Redundant | R |
| Output 1 Measuring range (Output for single circuit) | |
| Measuring range (indicate) ±10° ±15° ±20° ±30° ±45° ±60° ±85° (single axis Z for analogue output-dual axis XY); 360° (±180°) for single Z axis only | xxx |
| Output 2 Measuring range (Only for redundant version) | |
| Measuring range (indicate) ±10° ±15° ±20° ±30° ±45° ±60° ±85° (single axis Z for analogue output-dual axis XY); 360° (±180°) for single Z axis only | xxx |
| Supply voltage | |
| +5 V DC (only for A1 output) | L |
| 10 – 36 V DC (see output signal for right supply voltage) | H |
| Output type | |
| 0.5 – 4.5 V DC output (available with supply L = ratiometric output and with supply H = 0.5 – 4.5 V output) | A1 |
| 0 – 10 V DC output (powered at 11 – 36 V DC) | A2 |
| 4 – 20 mA output (powered at 10 – 36 V DC) | A3 |
| CANopen output (powered at 10 – 36 V DC) | C1 |
| Reserved | |
| Always | 0 |
| Certificate | |
| No certificate attached | 0 |
| Linearity curve to be attached | L |
| Version | |
| Standard | 33 |
| Accessories | |
| No accessories | X |
| Magnetic pen (PKIT 312) | Y |
| Cable length | |
| 100 mm | 1 |
| 200 mm | 2 |
| 500 mm | 5 |
| 1 m | 10 |
| 2 m | 20 |